SAKO 3KW on off grid hybrid solar inverter with energy storage
Features
1. Pure sine wave output
2. Self-consumption and Feed-in to the grid
3. Programmable supply priority for PV, Battery or Grid
4. User-adjustable battery charging current suits different types of batteries
5. Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
6. Built-in timer far various mode of on/off operation
7. Multiple communication far USB, RS-232, Modbus and SNMP
8. Monitoring Software for real time Status display and control
9. Parallel operation up to 6 units for 5KW and 10KW
Specification
SunKing is a flexible and intelligent hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power. It's a simple and smart solar power storage system for home users to either store energy into a battery and wait for night-time usage or use for self-consumption first depending on demands. Priority for power source can be programmed and set up through smart software. During night time or power failure, it will automatically extract power from the battery. In this way, it will reduce dependence on the utility.
MODEL | Sunking 3KW-PLUS | SunKing 5KW-PLUS | InfiniSolar 3P 10KW | ||||
PHASE | 1-phase in / 1-phase out | 3-phase in / 3-phase out | |||||
MAXIMUM PV INPUT POWER | 4500 W | 10000 W | 14850 W | ||||
RATED OUTPUT POWER | 3000 W | 5000 W | 10000 W | ||||
MAXIMUM CHARGING POWER | 1200 W | 4800 W | 9600 W | ||||
GRID-TIE OPERATION | |||||||
PV INPUT (DC) | |||||||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC | ||||
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 320 VDC / 350 VDC | ||||
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 400 VDC ~ 800 VDC | ||||
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A | 2 / 2 x 10 A | 2 / 2 x 18.6A | ||||
GRID OUTPUT (AC) | |||||||
Nominal Output Voltage | 208/220/230/240 VAC | 230 VAC (P-N) / 400 VAC (P-P) | |||||
Output Voltage Range | 184 - 265 VAC | 184 - 265 VAC* per phase | |||||
Nominal Output Current | 13 A | 21 A | 14.5A per phase | ||||
Power Factor | > 0.99 | ||||||
EFFICIENCY | |||||||
Maximum Conversion Efficiency (DC/AC) | 96% | ||||||
European Efficiency@ Vnominal | 95% | ||||||
OFF-GRID OPERATION | |||||||
AC INPUT | |||||||
AC Start-up Voltage/Auto Restart Voltage | 120 - 140 VAC / 180 VAC | 120 - 140 VAC per phase / 180 VAC per phase | |||||
Acceptable Input Voltage Range | 170 - 280 VAC | 170 - 280 VAC per phase | |||||
Maximum AC Input Current | 30 A | 40 A | |||||
PV INPUT (DC) | |||||||
Maximum DC Voltage | 500 VDC | 900 VDC | 900 VDC | ||||
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 400 VDC ~ 800 VDC | ||||
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A | ||||
BATTERY MODE OUTPUT (AC) | |||||||
Nominal Output Voltage | 202/208/220/230/240 VAC | 202/208/220/230/240 VAC | 230 VAC (P-N) / 400 VAC (P-P) | ||||
Output Waveform | Pure Sinewave | ||||||
Efficiency (DC to AC) | 93% | 91% | |||||
HYBRID OPERATION | |||||||
PV INPUT (DC) | |||||||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC | ||||
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 320 VDC / 350 VDC | ||||
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 400 VDC ~ 800 VDC | ||||
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A | ||||
GRID OUTPUT (AC) | |||||||
Nominal Output Voltage | 202/208/220/230/240 VAC | 202/208/220/230/240 VAC | 230 VAC (P-N) / 400 VAC (P-P) | ||||
Output Voltage Range | 184 - 264.5 VAC | 184 - 264.5 VAC per phase | |||||
Nominal Output Current | 13 A | 21 A | 14.5 A per phase | ||||
AC INPUT | |||||||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | 120 - 140 VAC per phase / 180 VAC per phase | |||||
Acceptable Input Voltage Range | 170 - 280 VAC | 170 - 280 VAC per phase | |||||
Maximum AC Input Current | 30 A | 40 A | |||||
BATTERY MODE OUTPUT (AC) | |||||||
Nominal Output Voltage | 202/208/220/230/240 VAC | 202/208/220/230/240 VAC | 230 VAC (P-N) / 400 VAC (P-P) | ||||
Efficiency (DC to AC) | 93% | 91% | |||||
BATTERY & CHARGER | |||||||
Nominal DC Voltage | 48 VDC | ||||||
Maximum Charging Current | Default 25A, 5A - 25A (Adjustable) | Default 60A, 5A - 100A (Adjustable) | Default 60A, 10A - 200A (Adjustable) | ||||
GENERAL | |||||||
PHYSICAL | |||||||
Dimension, D X W X H (mm) | 107 x 438 x 480 | 204.2 x 460 x 600 | 167.5 x 500 x 622 | ||||
Net Weight (kgs) | 15.5 | 29 | 45 | ||||
INTERFACE | |||||||
Communication Port | RS-232/USB | RS-232/USB and CAN Interface | |||||
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available | ||||||
ENVIRONMENT | |||||||
Humidity | 0 ~ 90% RH (No condensing) | ||||||
Operating Temperature | 0 to 40°C | -10 to 55°C | |||||
Altitude | 0 ~ 1000 m |
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on SAKO-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
Wholesale All Fnction Protection Hy-Brid Pure Sine Wave Solar Inverter
Wholesale All Fnction Protection Hy-Brid Pure Sine Wave Solar Inverter
Wholesale All Fnction Protection Hy-Brid Pure Sine Wave Solar Inverter
Contact Person : | Rachel |
---|